INSTALLATION AND OPERATING INSTRUCTIONS
C A U T I O N
To avoid electrical shock and
to prevent damage to the
INSTALLATION
Please read all instructions carefully
before beginning installation.
F
OF
furnace, air conditioner, and
thermostat, disconnect the power
PSPH521 SERIES
TOOLS REQUIRED
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations, mount the
supply before beginning work. This
can be done at the fuse box, at the
circuit breaker, or at the appliance.
PROGRAMMABLE HEAT PUMP THERMOSTAT
MO
UP
D
A
Y
HEAT
PM
DOWN
MO
UP
MO
UP
DAY
DAY
HEAT
HEAT
PM
DOWN
PM
DOWN
Easy as
1–2–3
SET
SATURDA
PROGRAM
SET
SUNDA
SET
SATURDA
PROGRAM
SET
SUNDA
Y
Y
Y
Y
RESET
RESET
PROGRAM
FAN
PROGRAM
FAN
HEA
T
HEAT
AUTO
AUTO
SET
WEEKDA
SET
WEEKDA
OFF
OFF
FILTER
HOLD
Y
FILTER
HOLD
ON
Y
ON
COOL
COOL
PROGRAM
PROGRAM
SET
DAY/TIME
RUN
SET
DAY/TIME
RUN
NEXT
NEXT
new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new
installations, follow the guidelines listed below.
1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is
used often.
2. Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot water pipes in a wall;
near a stove on the other side of a wall.
3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in
a draft from a stairwell, door, or window.
1500
a t e n t s P e n d i n g
1500
a t e n t s P e n d i n g
P
P
SIMPLIFIED INSTRUCTIONS
Press UP/DOWN to set time.
SIMPLIFIED INSTRUCTIONS
•
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
o clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
TO SET TIME
&
DAY
•
Press UP/DOWN to set time.
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
TO SET TIME
&
DA
Rotate Dial to SET
Y
•
•
Rotate Dial to SET
DAY/TIME.
TO SET PROGRAMS
•Rotate Dial to SET
•T
TO SET PROGRAMS
Rotate Dial to SET
•
T
o
DAY/TIME.
Press UP to change
•
Press UP to change
•
•
Installs Easily
Set Day & Time
Choose Heat or Cool
Complete, Easy To Read Programming And Installation Instructions Inside
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA
43343-04
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
Energizer® is a registered trademark of Eveready Battery Company, Inc.
DURACELL® is a registered trademark of The Gillette Company, Inc.
4. Do not locate in a damp area. This can lead to corrosion that will shorten
thermostat life.
5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open
door.
6. Do not install the unit until all construction work and painting has been completed.
7. This thermostat does not require leveling.
I M P O R T A N T !
Thank you for your confidence in our product. To obtain the best results from
your investment, please read these instructions and acquaint yourself with
READ
your purchase before installing your new thermostat. Then follow the
installation procedures, one step at a time. This will save you time and
minimize the chance of damaging the thermostat and the systems it controls.
These instructions may contain information beyond that required for your
particular installation. Please save for future reference.
INSTALLATION
INSTRUCTIONS
FIRST
REMOVING THE OLD THERMOSTAT
C A U T I O N
Switch electricity to the furnace and air conditioner OFF; then
Read instructions carefully
proceed with the following steps.
before removing any
1. Remove cover from old thermostat. Most are snap-on types
wiring from existing
and simply pull off. Some have locking screws on the side.
thermostat. Wires must be
These must be loosened.
FEATURES
labeled before they are
2. Note the letters printed near the terminals. Attach labels
The Active Program Period
LUX Speed Dial®
removed. When removing
•
The Unit can be
(enclosed) to each wire for identification. Remove and label
The Set
wires from their terminals,
used with most
Liquid Crystal
Display
wires one at a time. Make sure the wires do not fall back inside
Temperature
two stage heat
ignore the color of the
the wall.
and one stage
wires since these may not
comply with the standard.
3. Loosen all screws on the old thermostat and remove it from the
wall.
cool heat pump
systems. It cannot be
used with 120 volt
heating systems. Ask your
dealer for other LUX
thermostats to control those
systems.
MORN
DAY
UP
MOUNTING THE UNIT ON THE WALL
1. Strip insulation 3/8 in. (9.5mm) from wire ends and clean off any corrosion.
2. Fill wall opening with non-combustible insulation to prevent
drafts from affecting the thermostat.
3. Press up on the button on bottom of thermostat and swing the
body away from the base and up to remove the body from the
base.
EVE
DOWN
NIGHT
Thermostat
Body
RESET
SET
SET
WEEKDAY
WEEKEND
PROGRAM
PROGRAM
FAN
AUTO
ON
EMER
HEAT
OFF
System
Switch
HOLD
COOL
SET
RUN
DAYTIME
NEXT
•
•
The Unit is programmable.
There are four programming
periods per day. Each period
can be programmed
Fan
Switch
C
A
U
T
I
O
N
separately.
Be careful not to drop the body or disturb electronic parts.
You can use the built-in
time/temperature
programs, or alter them to
suit your schedule. The Unit
provides separate programs
for weekdays and weekends
- for both heating and
cooling. You can override the
programmed temperatures
for as little as one programming period or for an entire vacation.
Easy to
SIMPLIFIED INSTRUCTIONS
TO SET PROGRAMS
•Rotate Dial to SET WEEKDAY •Rotate Dial to SET
Leave the cover closed while the body is being removed from the base.
TO SET TIME
&
DAY
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period.
follow
or WEEKEND PROGRAM
•Press UP to change
current day.
•Press NEXT.
•Press UP/DOWN to set time.
WEEKDAY,
SATURDAY or
SUNDAY PROGRAM.
•Press UP/DOWN to adjust
start time.
instructions
TEMPERATURE HOLD
•Press HOLD. Adjust temperature as
desired with UP/DOWN.
•Press NEXT.
•Press UP/DOWN to adjust
temperature.
N O T E
•To clear, press HOLD again.
E
G
Y R O W2 B C
•Press NEXT.
Thermostat
Cover
TERMINALS
If you are mounting the base to
a soft material like plasterboard
or if you are using the old
•Repeat as needed or rotate
dial to RUN to stop
Programming.
Rotate the dial to the RUN position to close the door.
mounting holes, the screws
may not hold. Drill a 3/16-in.
(4.8mm) hole at each screw
location, and insert the plastic
anchors provided. Then mount
the base as described below.
•
•
•
In cool weather, when the system switch is set to HEAT, the Unit will maintain cooler “set back”
room temperatures to save energy. It will then change to warmer “comfort” settings — all
automatically, at specified times during the day.
In warm weather, when the system switch is set to COOL, the Unit will maintain warmer “set
back” room temperatures to save energy. It will then change to cooler “comfort” settings - all
automatically, at specified times during the day.
A large liquid crystal display shows time, day of the week, and room and set temperatures.
It will remind you when the filter should be changed in your blower and track your system’s
energy usage.
BASE
SCREW ANCHORS
Attaching Wires
4. Hold the base against the wall, with the wires coming through wherever
it is convenient for wiring. Route the wires to below the terminal block.
Position the base for best appearance (to hide any marks from an old
thermostat). Attach the base to the wall with the two screws provided.
•
•
•
Temperature swing adjustment lets you fine-tune your system for maximum comfort and
economy.
A 4-minute minimum on/off time in COOL prevents your air conditioning system from being
damaged.
The thermostat can be powered either by a common wire from the 24Vac transformer with
two Energizer® or DURACELL® "AA" size alkaline batteries as backup or exclusively by two
Energizer® or DURACELL® "AA" size alkaline batteries.
C
A
U
T
I
O
N
• Your thermostat is a precision instrument. Please handle it with care.
• Turn off electricity to the appliance before installing or servicing thermostat or any part
of the system. Do not turn electricity back on until work is completed.
• Do not short (jumper) across electric terminals at control on furnace or air conditioner
to test the system. This will damage the thermostat and void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt and millivolt systems. The thermostat
should be limited to a maximum of 1.0 amps; higher amperage may cause damage
to the thermostat. If you are in doubt, call your utility company.
© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
1