1). THERMOSTAT LOCATION  
For accurate temperature control and comfort, correct  
location is very important. On new installations, the  
guidelines listed below should be followed as closely as  
possible. When replacing an old thermostat, install the new  
one in the same location unless these conditions suggest  
otherwise.  
52014  
1. Locate the thermostat on an inside wall about five feet  
above the floor, where it is easy to install and adjust. It  
should be in a room that is used often, such as a  
family room.  
2. Do not install it where there are unusual heating  
conditions, such as direct sunlight, close to a lamp,  
radio, television, radiator, register, near a fireplace, or  
other heat producing appliance. Also, check for hot  
water pipes within the wall, or a stove on the other  
side of the wall.  
T10-1141SA  
3. Do not locate in unusual cooling conditions, such as on  
an outside wall, or one separating an unheated room, or  
in drafts from stairwells, doors, or windows.  
HEATING ONLY THERMOSTAT  
4. Do not locate in a damp or humid area. This can  
shorten thermostat life due to corrosion.  
5. Do not locate where air circulation is poor, such as in  
a corner, alcove, or behind an open door.  
6. Do not install until all construction work and painting  
have been completed.  
2) TOOLS REQUIRED  
Wirestripper or knife, drill with 316" bit, screwdriver, level  
and a pencil.  
3) REMOVING OLD THERMOSTAT  
Please read all instructions carefully. As you complete  
each step, check the adjoining square .  
Disconnect electricity and turn off gas to the heater.  
Remove cover from old thermostat.  
Loosen all screws.  
Disconnect wires from thermostat, making sure they do  
not fall back inside the wall.  
Strip insulation 3⁄  
" from wire ends and clean off any  
8
corrosion.  
Fill wall opening with non-combustible insulation to  
prevent drafts from  
affecting thermostat.  
4) INSTALLING NEW THERMOSTAT  
Place new decorative wall plate (if supplied), Figure 3,  
over wall opening. Decorative wall plate can optionally  
be left off.  
Remove Front Cover of new thermostat by inserting a  
finger in the side of the thermostat and gently prying  
away each corner. Place Base, Figure 2, on wall plate  
over wall opening. Mark wall with pencil at mounting  
holes as shown in Figure 2. Now lay wall plate and  
base to the side.  
SPECIFICATIONS  
ELECTRICAL RATING.............24 Vac (30 Vac Maximum)  
SWITCH ACTION ............................Open Contact Switch  
ANTICIPATOR RATING................................0.15A to 1.2A  
TEMPERATURE RANGE...............................50°F to 90°F  
Drill two holes with 316" bit, 1" deep.  
Insert plastic screw anchors into drilled holes, flush  
with wall surface.  
Bring wires through large hole in decorative wall plate  
and through Hole For Wires in Base.  
Fasten Base loosely to wall using two mounting  
screws. Place a level against the bottom of the Base,  
adjust until it is level and then tighten mounting screws  
to secure the Base.  
© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED  
href="
FIGURE 3 DECORATIVE WALL PLATE  
Attach wires to terminal screws shown in Figure 2.  
(Either wire to either terminal) Push excess wire back  
into wall opening.  
Find anticipator setting on old thermostat. Setting on  
new thermostat should be the same. Do this by  
carefully sliding the long pointer on the anticipator over  
the desired number. If old anticipator setting cannot be  
determined, look on gas control on furnace, or set it at  
.6. During heating season, furnace should operate  
about five times an hour. If adjustments are necessary,  
move heat anticipator pointer slightly and recheck.  
NOTE: Set pointer to 1.2 for millivolt systems.  
Attach front cover, Figure 1, to base.  
Turn electricity and gas back on and set pointer on top  
of thermostat to desired temperature.  
A thermostat can only control temperature near  
it. If you find that it is uncomfortable some  
distance away from the thermostat, change the  
setting in order to compensate for this.  
TECHNICAL ASSISTANCE  
If you have any problems installing or using this thermostat,  
please carefully and thoroughly review the instruction  
manual. If you require assistance, please contact our  
Technical Assistance Department at 856-234-8803 during  
regular business hours between 8:00AM and 4:30PM  
Eastern Standard Time, Monday through Friday. You can  
also receive technical assistance online anytime day or  
you answers to the most common technical questions, and  
also permits you to email your questions to our technical  
support staff at your convenience.  
FIGURE 1 FRONT COVER  
WARRANTY  
Limited Warranty: If this unit fails because of defects in  
materials or workmanship within three years of date of  
original purchase, LUX Products Corporation will, at its  
option, repair or replace it. This warranty does not cover  
damage by accident, misuse, or failure to follow installation  
instructions. Implied warranties are limited in duration to  
three years from date of original purchase. Some states do  
not allow limitations on how long an implied warranty lasts,  
so the above limitation may not apply to you. Please return  
malfunctioning or defective units to the participating retailer  
from which purchase was made, along with proof of  
purchase. Please refer to "TECHNICAL ASSISTANCE"  
before returning thermostat. Purchaser assumes all risks  
and liability for incidental and consequential damage  
resulting from installation and use of this unit. Some states  
do not allow the exclusion of incidental or consequential  
damages, so the above exclusion may not apply to you.  
This warranty gives you specific legal rights and you may  
also have other rights which vary from state to state.  
Applicable in the U.S.A. only.  
FIGURE 2 BASE  
MOUNTING HOLE  
UP  
RECYCLING  
NOTICE  
This product does not contain mercury. However, this  
product may replace a unit which contains mercury and  
should not be disposed of in the trash. Contact your local  
waste management authority for proper disposal  
instructions for mercury in a sealed glass tube.  
ANTICIPATOR  
E
LONG  
POINTER  
.5  
.3  
.4  