The Unit can be used with most 24 volt gas, oil or electric heating and air
conditioning systems, single-stage heat pumps or gas millivolt heating
systems. It cannot be used with 120 volt heating systems or multistage heat
pumps. Ask your dealer for other LUX thermostats to control those systems.
INSTALLATION AND OPERATING
INSTRUCTIONS
•
•
The Unit is programmable. There are four programming periods per day. Each
period can be programmed separately.
You can use the built-in time/temperature programs, or alter them to suit
your schedule. The Unit provides separate programming for every day of the
week- for both heating and cooling. You can override the programmed tempera-
tures for as little as one programming period or for an entire vacation.
In cool weather, when the system switch is set to HEAT, the Unit will maintain
cooler “set back” room temperatures to save energy. It will then change to
warmer “comfort” settings — all automatically, at specified times during the day.
In warm weather, when the system switch is set to COOL, the Unit will maintain
warmer “set back” room temperatures to save energy. It will then change to
cooler “comfort” settings - all automatically, at specified times during the day.
A large liquid crystal display shows time, day of the week, and room and set
temperatures. It will remind you when the filter should be changed in your blower
and track your system’s energy usage.
Temperature swing adjustment lets you fine-tune your system for maximum
comfort and economy.
A 4-minute minimum on/off time in COOL prevents your air conditioning
system from being damaged.
Two Energizer® or DURACELL® “AA” alkaline batteries (not included) are
used to retain your time and temperature programs.
TX9000 SERIES
SMART TEMP® ELECTRONIC THERMOSTAT
•
•
•
MO
UP
DAY
HEAT
PM
DOWN
MO
UP
MO
UP
DAY
DAY
Easy
as
HEA
T
HEA
T
PM
DOWN
PM
DOWN
S
S
P
ET
TURDA
ROGRAM
S
S
P
ET
UNDAY
S
S
P
ET
TURDA
ROGRAM
S
S
P
ET
UNDAY
A
Y
A
Y
RESET
RESET
ROGRAM
FAN
ROGRAM
FAN
HEA
T
HEAT
AUTO
AUTO
S
ET
WEEKDA
PROGRAM
OFF
S
ET
WEEKDA
ROGRAM
OFF
Y
FILTER
HOLD
Y
FILTER
HOLD
ON
ON
COOL
P
COOL
S
ET
RUN
S
ET
RUN
NEXT
DA
Y
/
TIME
NEXT
DA
Y
/
TIME
1500
P a t e n t s P e n d i n g
1500
P a t e n t s P e n d i n g
S
IMPLIFIED INSTRUCTIONS
TEMPORARY TEMPERATURE OVERRIDE
S
IMPLIFIED INSTRUCTIONS
TEMPORARY TEMPERATURE OVERRIDE
TO
S
ET TIME
&
DA
Y
•
Press UP/DOWN to set time.
TO
S
ET TIME
&
DA
Y
•
Press UP/DOWN to set time.
•
Rotate Dial to SET
DAY/TIME.
•Press UP/DOWN to adjust set temperature.
•
Rotate Dial to SET
DAY/TIME.
•Press UP/DOWN to adjust set temperature.
TO
S
ET
P
ROGRAMS
• Rotate Dial to SET
•T
o clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
TO
S
ET
P
ROGRAMS
• Rotate Dial to SET
•T
o clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
•
Press UP to change
•
Press UP to change
1–2–3
Installs Easily
Set Day & Time
Choose Heat or Cool
LUX PRODUCTS CORPORATION
Mt. Laurel, New J ersey 08054 USA
52002
•
•
•
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
Energizer® is a registered trademark of Eveready Battery Company, Inc.
DURACELL® is a registered trademark of The Gillette Company, Inc.
I M P O R T A N T !
C
A
U
T
I
O
N
• Your thermostat is a precision instrument. Please handle it with care.
• Turn off electricity to the appliance before installing or servicing
thermostat or any part of the system. Do not turn electricity back on
until work is completed.
Thank you for your confidence in our product. To obtain the
best results from your investment, please read these
READ
instructions and acquaint yourself with your purchase
before installing your new thermostat. Then follow the
installation procedures, one step at a time. This will save
INSTALLATION
• Do not short (jumper) across electric terminals at control on furnace or
air conditioner to test the system. This will damage the thermostat and
void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt and millivolt systems.
The thermostat should be limited to a maximum of 1.0 amps; higher
amperage may cause damage to the thermostat. If you are in doubt,
call your utility company.
you time and minimize the chance of damaging the
thermostat and the systems it controls. These instructions
may contain information beyond that required for your
particular installation. Please save for future reference.
INSTRUCTIONS
FIRST
FEATURES
INSTALLATION
The Active Program Period
The Set
Please read all instructions carefully before beginning installation.
Temperature
Liquid Crystal
Display
LUX Speed
Dial®
C
A U T I O N
TOOLS REQUIRED
To avoid electrical shock
and to prevent damage
to the furnace, air condi-
tioner, and thermostat,
disconnect the power
supply before beginning
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations,
mount the new thermostat in
place of the old one unless the
conditions listed below suggest
otherwise. On new installations,
follow the guidelines listed below.
Thermostat
Body
F
OF
work. This can be done at the
fuse box, at the circuit breaker, or
at the appliance.
System
Switch
1. Locate the thermostat on an
inside wall, about 5 ft. (1.5m)
above the floor, and in a room that is used often.
Fan Switch
2. Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near
hot water pipes in a wall; near a stove on the other side of a wall.
3. Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window.
PATENT NO. 5,673,850
SIMPLIFIED INSTRUCTIONS
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period.
TO SET TIME & DAY
TO SET PROGRAMS
Rotate Dial to SET
WEEKDAY,
•
Rotate Dial to SET
DAY/TIME.
•
•
Press UP to change
current day.
SATURDAY or
Easy to
SUNDAY PROGRAM.
Press UP/DOWN to adjust
start time.
•
•
Press NEXT.
Press UP/DOWN
to set time.
•
TEMPERATURE HOLD
•
follow
Press HOLD. Adjust temperature as
desired with UP/DOWN.
•To clear, press HOLD again.
•
•
Press NEXT.
Press UP/DOWN to adjust
temperature.
Press NEXT.
Repeat as needed or rotate
dial to RUN to stop Programming.
Instructions
4. Do not locate in a damp area. This can lead to corrosion that will shorten
thermostat life.
•
•
5. Do not locate where air circulation is poor, such as: in a corner or an alcove;
or behind an open door.
6. Do not install the unit until all construction work and painting has been
completed.
Thermostat
Cover
Button to Light
Display
7. This thermostat does not require leveling.
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED